熟女无套高潮内谢视频韩国,女人荫蒂全部过潮喷,老熟妇仑乱视频一区二,蜜芽忘忧草三区老狼大豆

您好,歡迎來到歐亞貿(mào)易網(wǎng)!請 |免費(fèi)注冊

產(chǎn)品展廳本站服務(wù)收藏該商鋪

CHANGSHA LANGSHUO TECHNOLOGY CO LTD

免費(fèi)會員
手機(jī)逛
CHANGSHA LANGSHUO TECHNOLOGY CO LTD
當(dāng)前位置:CHANGSHA LANGSHUO TECHNOLOGY CO LTD>>Alloy XFR Analyzer,Rohs Spectrometer>> LIBS HandHeld X series laser induced breakdown spectrometer

LIBS HandHeld X series laser induced breakdown spectrometer

產(chǎn)品二維碼
參  考  價(jià):面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)
  • 產(chǎn)品型號:
  • 品牌:
  • 產(chǎn)品類別:元素分析儀器
  • 所在地:
  • 信息完整度:
  • 樣本:
  • 更新時(shí)間:2025-07-14 12:53:13
  • 瀏覽次數(shù):6

聯(lián)系我時(shí),請告知來自 歐亞貿(mào)易網(wǎng)

CHANGSHA LANGSHUO TECHNOLOGY CO LTD

其他

  • 經(jīng)營模式:其他
  • 商鋪產(chǎn)品:911條
  • 所在地區(qū):
  • 注冊時(shí)間:2025-07-13
  • 最近登錄:2025-07-13
  • 聯(lián)系人:
產(chǎn)品簡介

LIBSHandHeldXserieslaserinducedbreakdownspectrometerTradedescriptionInrecentyears

詳情介紹

LIBS HandHeld X series laser induced breakdown spectrometer
Trade description

In recent years, laser-induced breakdown spectroscopy (LIBS) has become the preferred tool for geochemical analysis outside the traditional laboratory environment, testing a wide range of elements. Element measurement range atomic number. =1 (including organic elements such as C, H, O, light elements such as N, Li, Be, B, and almost all metals and non-metals) concentration range of 10ppm to % grade (depending on the element and instrument configuration) Analysis time generally about 20s sample form solid or powder (powder needs to be measured after pressing). Laser induced breakdown spectrometer is a new analytical means in the field of spectral analysis. Its basic principle is to use a high energy laser light source to form a high intensity laser spot (plasma) on the surface of the analytical material, so that the sample is excited to emit light, which is then analyzed by the spectral system and detection system. The e technique is sensitive to most inorganic elements in the material. At the same time, it can analyze low atomic number elements such as hydrogen – sodium elements, which are difficult to analyze with XRF technology

LIBS HandHeld X series laser induced breakdown spectrometer
Commodity parameter

Precise Elemental Analysis (LI-U)
The common handheld LIBS laser induced breakdown spectrometer (LIBS X-1688) is mainly used to test aluminum alloy, beryllium copper, carbon steel;
Specially made hand-held LIBS(LIBS X-898) for measurement of lithium in minerals, rocks and brines, pegmatite, clay and mica,

Intuitive operation
The Raspberry PI operating system and App-based software ensure quality inspection for each operator. Built-in WIFI and Bluetooth, with GPS capabilities, allows users to print, send , and connect to almost any information management system for full-featured reporting. Automatically merge XRF and LIBS test services to easily manage operations anywhere.

Designed for outdoor and laboratory use
KMX-RAY LIBS Series Handheld Analyzer Weighing 1.65kg with Battery 2pcs (14.4v)
High-resolution rear display for easy viewing; Strong metal body for maximum durability;
Conical narrow nozzle for use at inaccessible test sites;
Argon can be replaced by users for a few cents per test and hundreds of tests can be performed.
Pair with PC or tablet profile generator software and achieve full desktop functionality.

Laser induced breakdown spectrometer is a new analytical means in the field of spectral analysis. Its basic principle is to use a high energy laser light source to form a high intensity laser spot (plasma) on the surface of the analytical material, so that the sample is excited to emit light, which is then analyzed by the spectral system and detection system. The e technique is sensitive to most inorganic elements in the material. It can also analyze low atomic number elements such as hydrogen – sodium elements, which are difficult to analyze with other techniques.

LIBS HandHeld X series laser induced breakdown spectrometer
LIBS HandHeld laser-induced breakdown spectroscopy has powerful technical advantages:

· Almost all natural elements can Be measured, including H, Li, Be, C, N, O, S and other elements that are difficult to be analyzed by conventional methods;

· The sample preparation process is very simple, and the sample surface can be cleaned or the surface coating can be removed by means of repeated pulses;

· Only a few samples (1-10g) can be used for high-throughput analysis, greatly reducing the cost of analysis;

· With ppm level detection limit and high sensitivity, detection precision and accuracy;

· Nondestructive testing in the real sense, only a tiny amount of sample is consumed, laser incident on the sample will hardly produce heating effect;

· Elemental analysis can be performed on samples in any physical state, including solid, liquid, gas and various mixtures;

· Almost unaffected by spectral interference;

· For all detectable elements, the analysis time is reduced to about 20 seconds, which has a significant advantage over other analytical techniques;

· Good environmental adaptability, almost no special requirements. Just connect the power supply can work, do not need water cooling and compressed air. Can meet the requirements of field experiment;

· Basically no periodic replacement of consumables, equipped with laser can be continuously used for more than 600,000 times;

· Powerful analysis software and spectral database compatible with Windows operating system.

LIBS HandHeld X series laser induced breakdown spectrometer
LIBS HandHeld X-1688 aluminum alloy version

display3.5-inch resistive touch screen 320 by 480 pixels
Core technologyNo X-ray ionizing radiation based on LIBS laser technologymemoryInternal standard storage 32GB
Model numberLIBSHandheld X-1688laserClass 3B 1064nm passive solid-state laser
weight1.9 kgspectrograph<1.3nm resolution 170-1100nm spectral range
Size (length * width * height)250mm*75mm*250mmSingle test time3s
battery14.4V,6600mAh2 batteriesHigh precision test modeThe average value of multiple single test values can be analyzed by the algorithm
WIFI24GHz802.11n/b/a wireless networkAlloy matrixAluminum matrix
BLUETOOTHBluetooth4.1Classic Low Power BluetoothTestable elementAl, B, Be, Bi, Co, Cr, Cu, Fe, Li, Mg, Mn, Mo, Nb, Ni, Pb, SiSn Si, Ti, V, zinc, Zr, Le (residual elements)
Sample typeCylindrical thin sheet wire foil with diameter of 1mm or above (~0.02mm), large pieces (no powder)Operating temperatureStandard 0~40°C(32~100F) Recommended 5~35°C(40~95°F)
Detection lineIt varies according to different matrix and elementsRemote modeThe screen display can be projected onto a PC or mobile phone, and the test can be triggered remotely
databaseIncluding more than 100 most commonly used alloy brands available through KMAX software for advanced customizationsoftwareKmax client software (application update data download, brand library custom editing, test report generation, calibration file editing, etc.)
securityPhysical laser safety interlocking deviceExtended warranty serviceAn extended warranty is available by purchasing an extended warranty
Routine maintenanceClean sample room with cotton swabs Spot check with supplied alloy standard sample field calibration with specified alloy standard sample to improve accuracy

LIBS HandHeld X series laser induced breakdown spectrometer
LIBS HandHeld X-898 Ore Pro

technologyBased on plasma emission spectrometer technology, no X – ray radiation hazardDisplay screen35 inch resistive screen 320,480 pixels
Main engine (length * width * height)250mm*75mm*270mmmemory32G
Main machine quality (including battery)1.9kgSpectrometer parameter460-690nm(670nm for Carp peak) resolution 0.2nm, imported from the Netherlands spectrometer
Battery specification14.4V, 3300mAh/47.52Wh(16.8v Rechargeable)laser100A,14mJ.10Hz
Steam flaskSingle use of the gas bottle, 350 times dosage, purity of 99.99%Test sample typeBlock, flake, powder tablet
Data transmissionWIFI, Bluetooth, USBDetection limit0.01% – 99.99%.
Operating systemRaspberry PIRoutine maintenanceUse instrument cleaning kit to clean sample room, use sample control calibration instrument to improve accuracy
Operation languageChinese, English, Russian

LIBS HandHeld X series laser induced breakdown spectrometer LIBS HandHeld X series laser induced breakdown spectrometer LIBS HandHeld X series laser induced breakdown spectrometer LIBS HandHeld X series laser induced breakdown spectrometer LIBS HandHeld X series laser induced breakdown spectrometer LIBS HandHeld X series laser induced breakdown spectrometer LIBS HandHeld X series laser induced breakdown spectrometer LIBS HandHeld X series laser induced breakdown spectrometer

上一篇: Line Drying Time Recorder ASTM D 589
下一篇: Line Drying Time Recorder
同類優(yōu)質(zhì)產(chǎn)品

在線詢價(jià)

X

已經(jīng)是會員?點(diǎn)擊這里 [登錄] 直接獲取聯(lián)系方式

會員登錄

X

請輸入賬號

請輸入密碼

=

請輸驗(yàn)證碼

收藏該商鋪

X
該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
锡林郭勒盟| 怀化市| 桓台县| 原阳县| 淅川县| 孟村| 濉溪县| 清新县| 灵台县| 桦川县| 安吉县| 承德市| 福海县| 嘉禾县| 嵊州市| 额敏县| 高州市| 安泽县| 东源县| 龙井市| 扎兰屯市| 韩城市| 大丰市| 巴东县| 墨脱县| 南通市| 凌云县| 甘肃省| 塔城市| 本溪| 青铜峡市| 温州市| 南召县| 镇平县| 永州市| 沂南县| 澄迈县| 宜都市| 忻州市| 会理县| 安吉县|